Safety Technology


Wallner Automation is specialized on the development and manufacturing of safety solutions based on openSAFETY. Hereby we realize solutions up to KAT4/SIL3/PLe.

 

 

 


Safe digital input module

Safe digital input module

Development of a safe input module with connection to a proprietary bus system, developed according to corresponding norms, and assistance up to series production.

 

  • Two safe inputs according to KAT4 / SIL3 / PLe
  • Four clock outputs (OSSD), short circuit proof and overload safe executed
  • ARM7 processors by ATMEL
  • Communication via customer-specific protocol

Safe output module

Development of a safe output module with connection to a proprietary bus system developed according to corresponding norms and assistance up to series production.

 

  • Four fail-safe outputs according to KAT4 / SIL3 / PLe
  • Each output up to 2A / 24V
  • All outputs are overload- and short circuit safe
  • ARM7 processors by ATMEL
  • Communication with proprietary protocol

Safe CPU

Development of a safety CPU with two high performance Intel-processors, with which safety-relevant applications can be processed.

 

  • Fail-safe CPU according to KAT4 / SIL3 / PLe
  • 2-chanal structure
  • Two high-performance Intel-processors (XSCALE) with up to 466 MHz
  • Real-time clock up to 2 months buffered against power failure
  • Real-time Ethernet connection (Sercos III)